tig dc Art 557 big

 INVERTER MULTIVOLTAGE MMA AND PULSE DC TIG WELDING POWER SOURCE. HF IGNITION.

Art.557Specifications
 

TIG

MMA

 
mini

208-220-230V 
50/60 Hz
±10%

400-440V 
50/60 Hz
±10%

208-220-230V 
50/60 Hz
±10%

400-440V 
50/60 Hz
±10%

Three phase input

mini2

16 A

16 A

20 A

16 A

Fuse rating (slow blow)

mini3

7,8 KVA 35%
6,4 KVA 60%
5,4 KVA 100%

9,6 KVA 40%
7,8 KVA 60%
6,6 KVA 100%

9,3 KVA 35%
7,3 KVA 60%
6,4 KVA 100%

11,5 KVA 40%
9,3 KVA 60%
7,8 KVA 100%

Input power

mini4

5A ÷ 280A

5A ÷ 350A

10A ÷ 240A

10A ÷ 280A

Current adjustment range

mini5

280A 35%
245A 60%

220A 100%

350A 40%
280A 60%

250A 100%

240A 35%
200A 60%

180A 100%

280A 40%
240A 60%

210A 100%

Duty Cycle, (10 min.40°C)
according to EN 60974.1

mini9

IP 23 S

Protection class

mini10

78 Kg

Weight

mini11

705x1060x975H

Dimensions mm

WIN TIG DC 350 T (art. 557) is a three-phase inverter multi-voltage power source - 350 A 40% - 250 A 100% - for TIG and MMA/-SMAW use, with the exception of AWS6010 cellulosic electrodes.

Comes with cooling unit and trolley for transportation of the power source.

The new LCD colour display makes its use easy, quick and intuitive.

This new power source, in addition to the most common welding processes, is fitted with new ones, such as:

- TIG APC (Active Power Control), a welding process that allows to obtain colder welding beads 

- High quality arc ignition “EVO ST” in order to optimize the edge junction

- Spot and intermittence function

- Pulsed arc on low, medium, high and very high frequency for welding on small thickness where the transferred heat must be minimal

In TIG mode, the arc is started either on high frequency or by contact through the Cebora lift-system or EVO LIFT.

The power source is set up for remote control using the foot control (art. 193), remote control (art.187+1192) or Up-Down control on the torch (art. 1258).

The protection gases to be used are argon, argon/helium, argon/hydrogen.

It is also possible to memorize up to 9 welding programs (JOB).

The compliance with EN 61000-3-12 ensures a significant reduction in energy consumption and a wide supply voltage tolerance (+/- 10%).

The power source can be powered by motor-generators of adequate power.

Dokumentacija:

https://www.cebora.it/art_557_presentazione_prod_uk.html